CONSTRUCTION SPECIFICATIONS | |||
Description | Material | In. | (mm |
Inner Conductor | Stranded BC | 0.056 | (1.42) |
Dielectric | Foam Polyethylene | 0.150 | (3.81) |
Outer Conductor | Aluminum Tape | 0.155 | (3.94) |
Overall Braid | Tinned Copper | 0.178 | (4.52) |
Jacket | (See Table) | 0.240 | (6.10) |
ENVIRONMENTAL SPECIFICATIONS | ||
Performance property | OF | OC |
Installation Temperature Range | -40/+185 | -40/+85 |
Storage Temperature Range | -94/+185 | -70/+85 |
Operating Temperature Range | -40/+185 | -40/+85 |
ELECTRICAL SPECIFICATIONS | |||
Performance property | Units | US | (metric) |
Velocity of Propagation | % | 80 | |
Dielectric Constant | NA | 1.42 | |
Time Delay | nS/ft (nS/m) | 1.21 | (3.97) |
Impedance | ohms | 50 | |
Capacitance | pF/ft (pF/m) | 24.2 | (79.4) |
Inductance | uH/ft (uH/m) | 0.060 | (0.20) |
Shielding Effectiveness | dB | >90 | |
DC Resistance | |||
Inner Conductor | ohms/1000ft (/km) | 4.28 | (14.1) |
Outer Conductor | ohms/1000ft (/km) | 3.89 | (12.8) |
Voltage Withstand | Volts DC | 1500 | |
Jacket Spark | Volts RMS | 5000 | |
Peak Power | kW | 5.6 |
MECHANICAL SPECIFICATIONS | |||
Performance property | Units | US | (metric) |
Bend Radius: installation | in. (mm) | 0.75 | (19.1) |
Bend Radius: repeated | in. (mm) | 2.5 | (63.5) |
Bending Moment | ft-lb (N-m) | 0.125 | (0.17) |
Weight | lb/ft (kg/m) | 0.034 | (0.05) |
Tensile Strength | lb (kg) | 80 | (36.3) |
Flat Plate Crush | lb/in. (kg/mm) | 13 | (0.23) |